OSHA lightning guidance for construction: what it actually says

The short answer There is no OSHA lightning standard. OSHA and NOAA publish joint guidance, Fact Sheet 3863, and OSHA can cite a lightning hazard under the General Duty Clause. The guidance comes down to five things: have a written plan, watch the weather, stop when thunder is heard, get to real shelter, and wait at least 30 minutes after the last thunder before going back out.

Is there an OSHA lightning standard?

No. No OSHA regulation sets a lightning distance or a wait time. What exists:

If someone says "OSHA requires you to stop at 10 miles," the honest answer is that the 10-mile figure comes from the guidance, not from a rule. That doesn't make the guidance optional in practice. It's what a "recognized hazard" is measured against.

What the guidance asks employers to do

  1. Put it in writing. The fact sheet says employers should have a written emergency action plan that includes a lightning protocol for outdoor work.
  2. Check the forecast before work starts. Look at NOAA/National Weather Service forecasts before outdoor work begins.
  3. Keep watching during the day. Monitor conditions continuously, not just at the morning huddle.
  4. Know where shelter is and how long it takes to get there. Train workers on each site's shelter locations and the time needed to reach them. Our free toolbox talk covers that training in five minutes.
  5. Don't start what you can't stop. When storm signs appear, don't begin tasks that can't be stopped quickly.

When to stop work

The fact sheet's trigger is simple:

"If you hear thunder, even a distant rumble, get to a safe place immediately."

Where "10 miles" comes from. The guidance says lightning can strike up to 10 miles from any rainfall. That's roughly how far thunder carries, which is why hearing thunder means you're already within reach. Lightning detection systems turn the same idea into a measured distance: a strike within 10 miles of the site.

Why you can't wait for the trigger itself. On a jobsite, some work doesn't stop in seconds: a pour in progress, a load on the hook, a crew tied off on steel or working a roof. If the stop signal is the first thunder, that work is already late. Plans that work in practice build in an earlier heads-up, so crews can wrap up and get down before the stop point. The guidance's own advice not to start what you can't stop quickly says the same thing.

When to go back to work

Stay in shelter for at least 30 minutes after the last thunder you hear.

The part that gets skipped: every new thunderclap, or every new strike within range, restarts the 30 minutes. A lull between two storm cells is not the all-clear. Plans that just say "wait 30 minutes" without saying who keeps the clock, and who calls the restart, are where crews end up going back out early.

Safe shelter, and what isn't

Counts as shelterDoesn't
A fully enclosed building with electrical wiring and plumbingSheds, pavilions, tents or covered porches
If no building is available: a hard-topped metal vehicle with the windows rolled upAnywhere near isolated tall objects: trees, poles, cranes, scaffolding
Open ground, water, or metal fencing

Inside a building, stay away from things that conduct: corded phones, plumbing fixtures and plugged-in electrical equipment.

The fact sheet's own summary:

"There simply is no safe place outside in a thunderstorm."

Construction work the guidance singles out

The fact sheet lists roofing and construction work such as scaffolding among the higher-risk outdoor jobs. On a typical site, that means extra attention for:

What a lightning detection system can and can't do

The guidance mentions lightning warning and detection systems as part of a plan. It also says plainly that no system can detect the first strike, detect all lightning, or predict strikes, and that NOAA forecasts and weather reports come first.

That matches how any detection service works, including ours. A storm that moves in from a distance can be tracked as it closes. A cell that builds directly over a site can produce its first strike inside 10 miles with no warning beforehand. A detection system makes the stop and restart calls consistent and recorded. It doesn't replace watching the sky and the forecast.

If you're deciding between options, here's how the common ones compare.

Put it in writing

The guidance starts with a written plan. Our free jobsite lightning safety plan template is fill-in-the-blank and covers roles, the stop distance, shutdown order, shelters, the 30-minute restart and recordkeeping. You can download it as Word or PDF, with no email required.

Common questions

Can OSHA cite a company for a lightning hazard?

There's no lightning-specific rule to cite, but OSHA can use the General Duty Clause for recognized serious hazards. The OSHA/NOAA guidance is the most obvious description of what "recognized" looks like for lightning. This page is general information, not legal advice.

Does the guidance say 10 miles or "when you hear thunder"?

Both, in different words. The trigger it gives is hearing thunder. The 10-mile figure is how far from a storm lightning can strike. Detection systems use 10 miles because it can be measured, while hearing thunder depends on noise, wind and where you're standing.

Is 30 minutes measured from the last strike or the last thunder?

The fact sheet says the last thunder. Detection systems measure from the last strike within range, which is the same idea, measured instead of heard. Either way, every new one restarts the clock.

Do we need a weather monitor on every site?

The guidance says to monitor conditions continuously during outdoor work. It doesn't say how. That can be a person assigned to the job, a detection system, or both, as long as the plan names who's responsible.

Want the monitoring off someone's plate?

Lightning Ward watches for lightning around your jobsite and texts your crew at 20, 15 and 10 miles, then sends the all-clear after 30 strike-free minutes. Every new strike restarts the clock, and every stop alert and all-clear is logged.

This page summarizes OSHA/NOAA Fact Sheet 3863, Lightning Safety When Working Outdoors, for general information. It is not legal or safety-engineering advice. Read the fact sheet itself and follow your company's safety program.